Measurement of effective atomic number of gunshot residues using scattering of gamma rays

Yükleniyor...
Küçük Resim

Tarih

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

PERGAMON-ELSEVIER SCIENCE LTD

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

Better understanding of gunshot residues and the major elemental composition would be valuable to forensic scientists for their analysis work and interpretation of results. In the present work, the effective atomic numbers of gunshot residues (cartridge case, bullet core, bullet jacket and gunpowder) were analyzed using energy dispersive X-ray analysis (EDX). The scattering of 59.54 keV gamma rays is studied using a high-resolution HPGe detector. The experiment is performed on various elements with atomic number in the 4rZr82. The intensity ratio of coherent to Compton scattered peaks, corrected for photo-peak efficiency of gamma detector and absorption of photons in the sample and air, is plotted as a function of atomic number and constituted a best-fit-curve. From this fit-curve, the respective effective atomic numbers of gunshot residues are determined.

Açıklama

Anahtar Kelimeler

Gunshot residue, Effective atomic number, Coherent and Compton scattering, Energy dispersive X-ray analysis (EDX)

Kaynak

RADIATION PHYSICS AND CHEMISTRY

WoS Q Değeri

Scopus Q Değeri

Cilt

102

Sayı

Künye

YILMAZ, D., TURŞUCU, A., Uzunoğlu, Z., & KORUCU, D. (2014). Measurement of effective atomic number of gunshot residues using scattering of gamma rays. Radiation Physics and Chemistry, 102, 68–71.