Measurement on radiation shielding parameters of FexCr1_x and FexNix alloys

dc.contributor.authorTurşucu, Ahmet
dc.contributor.authorElmahroug, Youssef
dc.contributor.authorYılmaz, Demet
dc.date.accessioned2021-08-18T10:47:30Z
dc.date.available2021-08-18T10:47:30Z
dc.date.issued2021
dc.departmentFakülteler, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümüen_US
dc.description.abstractIn this present work, the gamma-ray radiation shielding parameters of nine different FexCr1-x. and FexNix alloys that were prepared at different mixture rates have been investigated. The gamma-ray shielding has different parameters which are total mass attenuation coefficient (µt), effective atomic number (Zeff) and effective electron density (Neff), half-value layer (HVL), tenth value layer (TVL), exposure buildup factor (EBF), energy absorption buildup factor (EABF) components. These shielding parameters have been measured experimentally by using gamma photons in the energy range from 0.0175 MeV to 0.05954 MeV. WinXCOM, ParShield and Phy-X program results were compared with values from experimental measurements used in characterizing the radiation shielding properties. The experimental mass attenuation coefficient values are in good concordance with the WinXCOM evaluations, with ranging from 0.04 to 13.21%. Also, the mass attenuation coefficient values derived using the ParShield and Phy-X simulations program have compared with WinXCOM. These values are quite agreed with the WinXCOM values. Additionally, in this work, the radiation shielding parameters are calculated by using experimental values and deviated values of theoretical calculations of WinXCOM, ParShield and Phy-X. It has been determined that the theoretical calculation programs are quite compatible. While some of the experimental radiation absorption findings almost exactly overlapped with the WinXCOM values, it was observed that there were acceptable differences with the ParShield and Phy-X values.en_US
dc.identifier.citationTurşucu, A., Elmahroug, Y. & Yılmaz, D. (2021). Measurement on radiation shielding parameters of FexCr1_x and FexNix alloys. Applied Physics A: Materials Science and Processing, 127(8), 0-0.en_US
dc.identifier.doi10.1007/s00339-021-04786-1
dc.identifier.issue8en_US
dc.identifier.orcid0000-0002-4963-697X
dc.identifier.scopus2-s2.0-85111765061
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://hdl.handle.net/11503/1662
dc.identifier.urihttps://doi.org10.1007/s00339-021-04786-1
dc.identifier.volume127en_US
dc.identifier.wosWOS:000691446800001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorTurşucu, Ahmet
dc.language.isoen
dc.publisherSpringer Science and Business Media Deutschland GmbHen_US
dc.relation.ispartofApplied Physics A: Materials Science and Processingen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBuildup factorsen_US
dc.subjectHVLen_US
dc.subjectMass attenuation coefficienten_US
dc.subjectTVLen_US
dc.titleMeasurement on radiation shielding parameters of FexCr1_x and FexNix alloysen_US
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Measurement-on-radiation-shielding-parameters-of-FesubxsubCrsub1xsub-and-FesubxsubNisubxsub-alloysApplied-Physics-A-Materials-Science-and-Processing.pdf
Boyut:
1.52 MB
Biçim:
Adobe Portable Document Format

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.43 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: